After-sales Service: | 1 Year |
---|---|
Warranty: | 1 Year |
Output Type: | AC Three Phase |
Samples: |
Customized according to demand
|
---|
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
Nor | materials | parameter | unit | index |
1 | liquid ammonia | Dosage | kg/h | 4000 |
pressure | MPa | 0.1~0.3 | ||
temperature | ºC | -10~0 | ||
2 | process water | Dosage | kg/h | 16000 |
pressure | MPa | ≥ 0.2 | ||
temperature | ºC | normal temperature | ||
3 | Cooling water ( When ΔT =5 ºC ) |
Dosage | kg/h | 120000 |
pressure | MPa | 0.2~0.4 | ||
temperature | ºC | 10~32 |
No | name | unit | Design Parameters |
|
work pressure | kPa | 200 |
|
Liquid ammonia dilution capacity | kg/h | 4000 |
|
Liquid ammonia pipeline pressure | MPa | 0.1~0.3 |
|
Ammonia production capacity | kg/h | 20000 (when ammonia concentration is 20%) |
|
Output ammonia concentration | % | 20 (5~32 continuously adjustable) |
|
Ammonia concentration control accuracy | % | ±0.3 |
|
Output ammonia temperature | ºC | 25 |
|
Process water for ammonia water preparation | Tap water, surface water, groundwater, pure water, dilute ammonia water, etc. | |
|
Process water consumption | kg/h | 16000 (when ammonia concentration is 20%) |
|
Process water supply pressure | MPa | ≥0.2 |
|
Process water temperature | ºC | normal temperature |
|
Cooling water consumption | kg/h | 120000 ( when ΔT =5 ºC ) |
|
Cooling water supply pressure | MPa | 0.2~0.4 |
|
cooling water temperature | ºC | 10~32 |
|
control method | Fully automatic closed-loop control | |
|
Usage environment | outdoor layout |
Preparator nozzle | unit | Specifications and standards |
Liquid ammonia import | mm | DN40 PN2.5MPa HG/T20592-2009 |
Process water import | mm | DN50 PN1.6MPa HG/T20592-2009 |
Cooling water import | mm | DN150 PN1.0MPa HG/T20592-2009 |
Cooling water outlet | mm | DN150 PN1.0MPa HG/T20592-2009 |
Ammonia export | mm | DN65 PN1.0MPa HG/T20592-2009 |
Suppliers with verified business licenses