Secured Trading Service

Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas

  • Audited Supplier
  • 9 yrs

Contact Supplier

Product Highlights

  • High Efficiency Power Generation: Achieves up to 12.15% power generation efficiency with 900 kW rated output.
  • Long Design Life: Unit design life is guaranteed for 18 years excluding wearing parts.
  • Low Noise Operation: Noise level is kept at or below 85 dB(A) measured at 1 meter distance.
  • Comprehensive Warranty: Includes 1-year warranty covering after-sales service and mechanical defects.
  • High Pressure Tolerance: Turbine handles working fluid maximum inlet pressure up to 3 MPa.
  • High Temperature Capability: Supports working fluid maximum entry temperature of 250 degrees Celsius.
  • Flexible Load Adjustment: Load adjustment range spans from 30% to 110% of rated capacity.
  • IP55 Protection Rating: Generator features IP55 degree of protection for safe industrial operation.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas

Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas pictures & photos
Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas pictures & photos
Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas pictures & photos
Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas pictures & photos
Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas pictures & photos
Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas pictures & photos
Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
  • Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
  • Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
    Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
  • Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
    Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
  • Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
    Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
  • Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
    Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
  • Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
    Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
  • Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas
    Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas

Find Similar Products

Product Description

ORC Turbine Generator,
Organic Rankine Cycle Generator for Industrial Use
4.1 Project heat source conditions
 
No project value unit Remark
1 Heat transfer oil flow ~ 360 m 3 /h  
2 Heat transfer oil supply temperature ~ 220 ºC  
3 Heat transfer oil return oil temperature ~ 180 ºC  
4 Heat transfer oil specific heat capacity ~ 2.538 kJ/kg·ºC @ 200 °C
5 Heat transfer oil density ~ 732.8 kg g / m3 @ 200 °C
6 Thermal oil heat release power ~ 7,439 kW  
4.2 Performance parameter table of waste heat generating set
No project value unit Remark
1 input thermal power ~ 7,439 kW  
2 Installed power ~ 1,000 kW  
3 Generating power ~ 900 kW  
4 power generation efficiency ~ 12.15 %  
5 Net generating power [1] ~ 760 w _  
6 cold water inlet temperature ~3 0 ºC  
7 cold water temperature ~40 ºC  
8 cooling water flow ~ 560 t/h  
9 Condensing power ~ 6 , 540 kW  
10 Organic working fluid pump power consumption ~9 7 kW  
1 1 Cooling water circulation pump power consumption ~ 33 kW  
1 2 Heat transfer oil pump power consumption ~ 10 kW  
Note: [1] The net generating power is the power after deducting the power consumption of organic working medium pump, cooling water circulation pump and heat transfer oil working medium pump.
4.3 Turbine performance parameter table
No project value unit Remark
1 Installed power ~ 1,000 kW  
2 rated power ~ 900 kW  
3 Axial series 4 class  
4 working fluid maximum inlet pressure 3 M P a Except for special models
5 Working fluid maximum entry temperature 250 ºC Except for special models
6 Work substance R 245 fa    
7 isentropic efficiency ≥ 82 %  
8 Load adjustment range ~ 3 0~1 1 0 %  
9 noise level ≤85 dB(A) (@1 meter)
1 0 Unit design life ≥ 18 Year In addition to wearing parts
4.4 Generator performance parameter table:
No project value unit Remark
1 Installed power ~ 1,000 KW  
2 Rated output voltage 400 V  
3 rated frequency 50 Hz  
4 Phase 3 Mutually  
5 power factor 0.8 -  
6 Rated speed 1,500 rpm  
7 Insulation class f class  
8 installation method B3 -  
9 degree of protection I P55 - Tentative
1 0 Explosion-proof grade none -  
  1. Turbine generator Quotation List
No Device name parameter quantity unit Remarks
1 Turbine ~ 1 , 0 00kW 1 set Turbine + Generator
2 Lubricating oil skid station - 1 set
3 Generator ~ 1 , 0 00kW 1 set
4 Pry rack   1 set
5 Shipping fee to China port - 1 set
6 Fees for distance technical services   1 set



Organic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas

Organic Rankine Cycle Generator, Orc Turbine Generator From Waste GasOrganic Rankine Cycle Generator, Orc Turbine Generator From Waste GasOrganic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas

Organic Rankine Cycle Generator, Orc Turbine Generator From Waste GasOrganic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas



Organic Rankine Cycle Generator, Orc Turbine Generator From Waste GasOrganic Rankine Cycle Generator, Orc Turbine Generator From Waste GasOrganic Rankine Cycle Generator, Orc Turbine Generator From Waste Gas













 
 

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASI242085". Items marked "verified" are certified.

Watch Video
Watch Video
Markevina Technology (Shenzhen) Co., Ltd.
Markevina Technology (Shenzhen) Co., Ltd.
Markevina Technology (Shenzhen) Co., Ltd.
Markevina Technology (Shenzhen) Co., Ltd.
Markevina Technology (Shenzhen) Co., Ltd.
Markevina Technology (Shenzhen) Co., Ltd.
Markevina Technology (Shenzhen) Co., Ltd.
Markevina Technology (Shenzhen) Co., Ltd.

About Our Factory & Business Background

Address
Longhua, Shenzhen, Guangdong, China
Terms of Payment
LC, T/T, Western Union
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DAT, FAS, DAP, CIP, CPT, FCA
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
Nearest Port
Shenzhen, Zhongshan, Guangzhou

Our Production Capability & Technical Expertise

Main Products
Small Home Appliances, Electricity and Power Equipment Manufacturing, Machinery and Production Line

Our Industry Experience & Global Business Record

Export Year
2015-09-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the rated power of the turbine?
The turbine has a rated power of 900 kW and an installed power of 1,000 kW.
How long is the warranty period?
We provide a 1-year warranty for after-sales service and mechanical coverage.
What is the maximum operating temperature?
The working fluid maximum entry temperature is 250 degrees Celsius.
What is the expected lifespan of the unit?
The unit design life is at least 18 years, excluding wearing parts.
What is the noise level of the generator?
The noise level is less than or equal to 85 dB(A) at a distance of 1 meter.
What is the power generation efficiency?
The system achieves a power generation efficiency of approximately 12.15%.
What is the load adjustment range?
The load can be adjusted between 30% and 110% of the rated power.
What is the maximum inlet pressure?
The maximum inlet pressure for the working fluid is 3 MPa.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

People who viewed this also viewed